Cast iron development pump submersible sewage and drinking water pumps
EPTT Data
The EPTT WQ Collection SubmersibleSewage EPTs are electro submersible centrifugal pumps created for pumping waste h2o, effluent and solids laden drinking water in municipal, EPTT, mining and civil development purposes.
Apps
Transfer of waste water, effluent and solids
laden drinking water for:
#8226 JCEP Treatment
#8226 EPTT Services
#8226 Sumps and Basements
#8226 EPT
#8226 Civil EPTT
#8226 JCEP
#8226 EPT
#8226 Processing
EPTnical Information:
Kind | Centrifugal | Submersible | ||
Medium | Sewage | Squander water | Rain water | Living h2o |
Flowrate | Min.:10m3/h | Max.:6000m3/h | ||
EPT | Min.:7m | Max.:62m |
Functions:
#8226 EPT power cast iron pump development.
#8226 EPTTeller choices are obtainable to match a assortment of programs and pumped goods incXiHu (West EPT) Dis.Hu (West EPT) Dis. one, double or triple vane.
#8226 420 Stainless steel shaft.
#8226 Created in cooling technique makes it possible for operation when motor is submerged or over h2o amount.
#8226 Optional external cooling offered.
#8226 Cast iron replaceable neck ring insert.
#8226 Class F motor insulation with maXiHu (West EPT) Dis.mum operating temperature of up to a hundred and fifty five degC.
#8226 IPX8 motor security.
#8226 Twin mechanical seals with carbide/tungsten seal faces on pump aspect and graphite/silicon carbide faces on motor facet offer effective sealing in between motor and wet stop.
#8226 EPT seals are oil tub lubricated.
#8226 EPT stator incorporates 3 shutdown temperature handle sensors which routinely detects motor temperatures at a hundred twenty five degC.
#8226 Oil chamber incorporates a water leakage probe which detects when drinking water-to-oil ratio is as well substantial and cuts off EPTT to avert motor injury due to oil contamination.
#8226 EPT incorporates h2o detection sensor at the best and a float swap in the bottom to detect the ingress of water and lower EPTT to avert motor harm.
#8226 Obtainable with a broad variety of protecting coatings and paint choices.
#8226 Optional product grinders available on ask for.
#8226 Optional computerized coupling system offered to enable basic maintenance and servicing.
#8226 Delicate steel outlet pipe set up with flanged connections as stXiHu (West EPT) Dis.Hu (West EPT) Dis.rd.
#8226 Optional comfortable outlet pipe set up obtainable to let swift and easy mounting and elimination when JCEP.
#8226 Optional set dry set up available with external cooling drinking water.
EPTs
Description | StXiHu (West EPT) Dis.Hu (West EPT) Dis.rd EPT | EPT Options |
Shaft | 420 Stainless Metal | |
EPT Casing | Cast Iron | SS316/ Duplex |
EPTTeller | Forged Iron | SS316/ Duplex |
Neck Ring | Cast Iron | SS316/ Duplex |
EPT JCEP Jacket | Mild Steel | SS316 |
EPT EPT Seal | SS304 | |
Soaked End EPT Seal | SS304 | |
EPT Entire body | Solid Iron | SS316 |
Oil EPT | Solid Iron | SS316 |
Problems of use
1. Medium temperature need to not be above 40degree, the density no more substantial than 1200kg/m, and the PH value within5-nine.
two. Throughout working, the pump need to not be reduce than the most affordable liquid degree.
3. The maXiHu (West EPT) Dis.mum diameter of the strong grain likely by way of the pump has not be larger than fifty% of the pump outlet.
Structures Description
EPTT | EPTTorted and Regional market place brand name |
Cooling | Built-in cooling technique |
EPT | F course insulation, max. functioning temperature 155degree |
Seal | EPT seal |
Oil chamber | Oil can lubricate and cool the mechanical seal |
EPTTeller | Optimized design and style |
EPT casing | CAD/CAM design and style |
Float switch | warning signal |
WQ EPT Efficiency
Item | Variety | Outlet diameter (mm) | Capability (m3/h) | EPT (m) | Velocity (r/min) | EPTT (kw) | Efficiency (%) |
1 | 50WQ15-eight-.75 | fifty | ten-twenty | 7-10 | 2825 | .75 | fifty two |
two | 50WQ15-sixteen-1.5 | 50 | ten-twenty | ten-eighteen | 2840 | 1.five | fifty two |
three | 65WQ30-ten-2.two | 65 | twenty-45 | 8-twelve | 1420 | two.two | sixty two |
four | 65WQ30-35-seven.five | sixty five | 20-45 | 30-37 | 1440 | seven.five | fifty |
5 | 80WQ50-35-eleven | eighty | forty-75 | 27-forty | 2900 | eleven | 55 |
six | 80WQ50-40-15 | eighty | 40-75 | 37-42 | 2900 | 15 | 52 |
seven | 100WQ80-36-18.5 | a hundred | sixty five-a hundred and twenty | 30-40 | 2900 | eighteen.five | 55 |
eight | 100WQ80-40-22 | 100 | 65-one hundred twenty | 35-forty five | 2900 | 22 | fifty five |
9 | 150WQ150-40-30 | 150 | a hundred-200 | 33-42 | 1470 | 30 | 65 |
ten | 200WQ400-27-forty five | two hundred | 250-five hundred | 24-35 | 1480 | 45 | 74 |
eleven | 250WQ500-twenty five-fifty five | 250 | four hundred-seven-hundred | sixteen-22 | 980 | 55 | seventy four |
twelve | 300WQ1000-20-75 | 300 | 800-1400 | fifteen-23 | 990 | seventy five | 82 |
thirteen | 350WQ1100-25-a hundred and ten | 350 | 900-1500 | eighteen-thirty | 980 | one hundred ten | 76 |
14 | 350WQ1500-forty-250 | 350 | 1200-2000 | 33-forty two | 740 | 250 | eighty |
fifteen | 400WQ2000-36-280 | four hundred | 1500-2800 | 27-43 | 745 | 280 | 80 |
sixteen | 500WQ3000-11-132 | 500 | 2000-4000 | 8-14 | 745 | 132 | 75 |
seventeen | 600WQ4000-12-two hundred | 600 | 3000-6000 | seven-sixteen | 745 | 200 | 72 |
The earlier mentioned pump functionality for reference only, specifics you should make contact with us!
FAQ
A: What variety of firm you are?
Q: ShiEPTTzhuang EPTT EPT EPTT is specialist company in pumps. Following accumulation and deveXiHu (West EPT) Dis.Hu (West EPT) Dis.ment of numerous many years, we have fashioned a full method of pump design and style, assortment, application, manufacture, marketing and advertising and upkeep. We have handed CE, SGS certificate. Our buyers are at home and abroad. Hope to coorperate with the worldwide friends.
Q: What’s your MOQ?
A: Trial sample orEPTTis Okay.
Q: What are your payment conditions?
A: T/T, L/C, D/P, D/A or as consumer JCEP
Q: How about the warranty?
A: 1 yr guarantee for pumps, it relies upon on other pump doing work situation particulars.
Q: What is the delivery time?
A: 7-30 daEPTTaccording to consumer portions.
Q: Can you do OEM brand?
A: Indeed, Welcome.
Q: What details should I offer you to get pump solution?
one, EPT: m
two, Stream: m3/h
three, Max JCEP measurement: mm
four, Particle shape (sleek or sharp):
5, Medium pH amount:
six,Certain Gravity of the Medium:
seven, Temperature:
8, JCEP type:
nine. EPTT supply: JCEP or Dlesel
ten, Voltage and Frequency of the EPT:
Welcome inquiry!
Serena EPT
Speak to:
Mob: 158 3083 2057
Tel: 312 8929296
Fax: 312 357183