China wholesaler Customized Jaw Spider Couplings Jaw-Type Curved Jaw Coupling

Product Description

1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111

Item No. φD L L1 W M Tighten the strength(N.m)
SG7-11-30- 30 50 18.5 13 M3(4) 1.2
SG7-11-40- 40 66 25 16 M4(6) 2.7
SG7-11-55- 55 78 30 18 M5(4) 6
SG7-11-65- 65 90 35 20 M5(6) 6
SG7-11-80- 80 114 45 24 M6(8) 10
SG7-11-95- 95 126 50 26 M8(4) 35
SG7-11-105- 105 140 56 28 M8(4) 35

111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111

Item No. Rated torque Maximum Torque Max Speed Inertia Moment N.m rad Tilting Tolerance End-play Weight:(g)
SG7-11-30- 7.4N.m 14.8N.m 20000prm 8.7×10-4kg.m² 510N.m/rad 1.0c +0.6mm 50
SG7-11-40- 9.5N.m 19N.m 15000prm 1.12×10-3kg.m² 550N.m/rad 1.0c +0.8mm 120
SG7-11-55- 34N.m 68N.m 13000prm 4.5×10-3kg.m² 1510N.m/rad 1.0c +0.8mm 280
SG7-11-65- 95N.m 190N.m 10500prm 9.1×10-3kg.m² 2800N.m/rad 1.0c +0.8mm 450
SG7-11-80- 135N.m 270N.m 8600prm 1.9×10-2kg.m² 3600N.m/rad 1.0c +1.0mm 960
SG7-11-95- 230N.m 460N.m 7500prm 2.2×10-2kg.m² 4700N.m/rad 1.0c +1.0mm 2310
SG7-11-105- 380N.m 760N.m 6000prm 3.3×10-2kg.m² 5800N.m/rad 1.0c +1.0mm 3090

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

jaw coupling

Electrical Insulation in Jaw Couplings

Jaw couplings are designed to provide mechanical connection between two shafts while also maintaining electrical insulation. This feature is essential in applications where the connected shafts have different electrical potentials or where electrical isolation is required to prevent current flow between the shafts.

The electrical insulation in jaw couplings is primarily achieved through the use of non-conductive materials for the jaw components. The jaws of the coupling are typically made from materials such as elastomers or plastics, which are excellent electrical insulators. These non-conductive materials prevent electrical conduction between the two shafts, even if they are made from different conductive materials.

Additionally, the design of the jaw coupling ensures that the two shafts do not come into direct electrical contact with each other. The jaws of the coupling create a gap between the shafts, which further enhances the electrical insulation.

It’s important to note that while jaw couplings provide electrical insulation, their primary function is to transmit torque and accommodate misalignment between shafts. If specific electrical insulation requirements are critical for an application, additional measures such as insulating sleeves or shaft grounding may be necessary in conjunction with the jaw coupling.

Overall, jaw couplings are a reliable and widely used choice for mechanical power transmission while ensuring electrical isolation between connected shafts.

jaw coupling

What are the common installation mistakes to avoid when using jaw couplings?

Proper installation of jaw couplings is crucial to ensure their reliable and efficient operation. Avoiding common installation mistakes can prevent premature wear, misalignment, and potential equipment damage. Here are some of the most common installation mistakes to avoid when using jaw couplings:

  1. Incorrect Coupling Size: Using the wrong size of jaw coupling for the application can lead to various issues. Undersized couplings may not handle the required torque, leading to early failure, while oversized couplings may result in increased rotational inertia and decreased system performance. Always ensure that the selected coupling is appropriate for the torque and power requirements of the equipment.
  2. Misalignment: Improper alignment of the shafts during coupling installation can cause excessive forces and premature wear on the coupling components. Angular, parallel, and axial misalignments should be minimized and kept within the manufacturer’s recommended tolerances. Consider using alignment tools and techniques to achieve accurate shaft alignment.
  3. Over-Tightening: Applying excessive torque when tightening the coupling elements can lead to deformation of the elastomer spider or damage to the hubs. Over-tightening can also increase friction and cause premature wear. Follow the manufacturer’s specified torque values during installation to ensure proper clamping without causing damage.
  4. Lack of Lubrication: Some jaw couplings require lubrication to reduce friction and wear. Neglecting to lubricate the coupling elements can lead to increased friction, higher operating temperatures, and reduced coupling life. Follow the manufacturer’s guidelines regarding lubrication intervals and types of lubricants to use.
  5. Failure to Inspect Components: Before installation, carefully inspect all coupling components for any signs of damage, wear, or defects. Using a damaged or worn-out elastomer spider or other components can compromise the coupling’s performance and reliability. Replace any worn or damaged parts before installing the coupling.
  6. Improper Shaft End Preparation: Ensure that the shaft ends are clean, smooth, and free from burrs or imperfections before installing the coupling. Rough or uneven shaft surfaces can lead to misalignment and reduce coupling performance. Properly clean and prepare the shaft ends to ensure a secure and accurate fit.
  7. Not Following Manufacturer’s Guidelines: Each jaw coupling has specific installation instructions provided by the manufacturer. Failure to follow these guidelines can result in coupling failure or reduced performance. Always refer to the manufacturer’s installation manual and recommendations for proper installation procedures.

By avoiding these common installation mistakes, users can maximize the performance and longevity of jaw couplings in their applications. Proper installation ensures that the coupling operates efficiently, transmits power effectively, and reduces the risk of unexpected failures or downtime.

jaw coupling

How Does a Jaw Coupling Protect Connected Equipment from Shock Loads and Vibrations?

Jaw couplings are designed to provide some level of flexibility, which allows them to absorb shock loads and dampen vibrations in mechanical systems. The unique design of jaw couplings contributes to their ability to protect connected equipment in the following ways:

  • Spider Element: The spider element, typically made of elastomeric material, serves as a mechanical fuse in the jaw coupling. When the system experiences shock loads or vibrations beyond the coupling’s rated capacity, the spider element can deform or fail in a controlled manner, protecting the connected components from damage.
  • Torsional Wind-Up: In the presence of torsional vibrations or sudden torque fluctuations, the elastomeric spider can act as a torsional buffer, absorbing and dissipating the energy to prevent it from reaching the connected equipment.
  • Misalignment Compensation: Jaw couplings can tolerate a degree of angular, parallel, and axial misalignment between the shafts. This capability helps minimize stress on the connected components in situations where misalignments might occur due to external forces or dynamic operating conditions.
  • Reduction of Resonance Effects: The flexibility of jaw couplings can help mitigate resonance effects that may arise in the system, reducing the risk of resonance-related failures or damages.

It’s important to note that while jaw couplings offer protection against certain shock loads and vibrations, they have their limits. Excessive or repetitive shocks, vibrations, or overloading beyond the coupling’s rated capacity can still lead to premature wear or failure. Therefore, it is essential to select the appropriate size and type of jaw coupling for the application and regularly inspect the coupling for signs of wear or damage. Regular maintenance and inspection help ensure the jaw coupling continues to provide reliable protection to the connected equipment.

China wholesaler Customized Jaw Spider Couplings Jaw-Type Curved Jaw Coupling  China wholesaler Customized Jaw Spider Couplings Jaw-Type Curved Jaw Coupling
editor by CX 2024-04-19

Recent Posts